'15 • SRK-T-171
1. SPECIFICATIONS
Model
Item
SRK05CR-S
Indoor unit SRK05CR-S Outdoor unit SRC05CR-S
Cooling capacity (1) W 1465
Power source 1
Phase, 220-240V, 50Hz
Operation
data
Power
consumption
Cooling kW 0.375
Running
current
Cooling
A
1.70
Inrush current 10
COP Cooling 3.91
Noise
level
Cooling
Sound level dB(A) 42 48
Power level dB 56 59
Exterior dimensions (Height x Width x Depth) mm 262 x 615 x 210 435 x 645 (+50) x 275
Exterior appearance
(Munsell color)
Fine snow
(8.0Y 9.3/0.1) near equivalent
Stucco white
(4.2Y 7.5/1.1) near equivalent
Net weight kg 6 20
Refrigerant
equipment
Compressor type & Q'ty — GAB046PAA (Rotary type) x 1
Motor (Starting method) kW — PSC
Refrigerant oil
ℓ
0.23 (POE [RB68A] or PVE [FVC68D])
Refrigerant (4) kg R410A 0.46 ( Pre-charged up to the piping length of 5m )
Heat exchanger Louver fins & inner grooved tubing Louver fins & inner grooved tubing
Refrigerant control Capillary tubes
Device control Microcomputer control
Air handling
equipment
Fan type & Q'ty Cross flow fan x 1 Propeller fan x 1
Motor W 17 22
Air flow Cooling m
3
/min 8.5 23
Fresh air intake Not possible —
Air filter, Quality / Quantity Polypropylene net (washable) x 1 —
Shock & vibration absorber — Cushion rubber (for compressor)
Operation
control
Operation switch Wireless remote control —
Room temperature control Microcomputer thermostat —
Operation display RUN : Green, TIMER : Yellow
Safety devices
Compressor overheat protection, Overcurrent protection,
Frost protection, Serial signal error protection, Indoor Fan motor error protection,
Cooling overload protection
Installation
data
Refrigerant piping size (O.D) mm Liquid line:
φ
6.35 (1/4") Gas line:
φ
9.52 (3/8")
Connecting method Flare connecting
Attached length of piping m
Liquid line : 0.46
Gas line : 0.40
—
Insulation for piping Necessary (Both sides), independent
Refrigerant line (one way) length
m
Max. 15
Vertical height difference between
outdoor unit and indoor unit
Max.5 (Outdoor unit is higher)
Max.5 (Outdoor unit is lower)
Drain hose Connectable (VP 16) —
Power cable —
Recommended breaker size A 10
Connection wiring
Size x Core number 1.5mm
2
x 3 cores (Including earth cable)
Connecting method Terminal block (Screw fixing type)
Accessories (included) Mounting kit
Option parts —
Note (1) The data are measured at the following conditions.
Item
Operation
Indoor air temperature Outdoor air temperature
Standards
DB WB DB WB
Cooling 27˚C 19˚C 35˚C 24˚C ISO-T1, JIS C 9612
(2) This air-conditioner is manufactured and tested in conformity with the ISO.
(3) The operation data are applied to the 220V districts respectively.
(4) The refrigerant quantity to be charged includes the refrigerant in 5m connecting piping.
(Purging is not required even for the short piping.)
If the piping length is 5m to 15m, additional refrigerant is 10g per each 1m longer than 5m.
The pipe length is 5m.