129
-
(2) The operation data are applied to the 220 V districts respectively.
(3) The refrigerant quantity to be charged includes the refrigerant in 7.5 m connecting piping.
(Purging is not required even in the short piping.)
If the piping length is longer, when it is less than 10 m, add 10 g refrigerant per meter and when it is 10 to 15 m, add 30 g refrigerant per meter.
(4) Expressed in sound pressure level.
Notes (1) The data are measured at the following conditions.
Item
Model
SRK13CES SRC13CES
Cooling capacity
(1)
W 3800
Power source 1 Phase, 220V, 50Hz
Cooling input kW 1.16
Running current (Cooling) A 5.7
Inrush current A 33.2
COP (In cooling) 3.27
Noise level
(4)
dB 41 49
Exterior dimensions
mm 250 × 815 × 249 640 × 850 × 290
Height × Width × Depth
Color Cool white Stucco white
Net weight kg 10.5 40
Refrigerant equipment
RM5517FNE41
Compressor types & Qty
Motor kW 1.3
Starting method Line starting
Heat exchanger Louver fins & tubing
Refrigerant control Capillary tubes
Refrigerant
(3)
kg R22 1.2 (Pre-Charged up to the piping length of 7.5m)
Refrigerant oil R 0.6 (BARREL FREEZE 32SAM)
Air handling equipment
Tangential fan × 1 Propeller fan × 1
Fan type & Qty
Motor W 14 35
Air flow (at High) CMM 9.0 39.5
Air filter, Qty Polypropylene net (washable) × 2
Shock & vibration absorber Cushion rubber (for compressor)
Electric heater ––
Operation control
Wireless-Remote control
Operation switch
Room temperature control Microcomputer thermostat
Pilot lamp RUN (Green), TIMER (Yellow),
HI POWER (Green), ECONO (Orange)
Safety equipment Frost protection,
Internal thermostat (for compressor)
Fan motor error protection
O.D mm (in) Liquid line: ø6.35 (1/4") Gas line: ø12.7 (1/2")
Connecting method Flare connecting
Attached length of piping Liquid line: 0.4 m
Gas line : 0.33 m
Insulation Necessary (Both sides)
Drain hose Connectable
Power source cord 2.5 m (3 cores with Earth)
Size × Core number 1.5 mm
2
× 3 cores (Including earth cable)
Connecting method Terminal block (Screw fixing type)
Accessories (included) Mounting kit
Optional parts
Connection
wiring
Operation
data
(1)
Refrigerant
piping
Item Indoor air temperature Outdoor air temperature
Standards
Operation DB WB DB WB
Cooling 27°C19°C35°C24°C ISO-T1, JIS C9612
Model SRK13CES (Indoor unit)
SRC13CES (Outdoor unit)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi SRK13CES and is the answer not in the manual?

Mitsubishi SRK13CES Specifications

General IconGeneral
BrandMitsubishi
ModelSRK13CES
CategoryAir Conditioner
LanguageEnglish

Related product manuals