EasyManuals Logo
Home>Mitsubishi>Air Conditioner>SRK13CES

Mitsubishi SRK13CES User Manual

Mitsubishi SRK13CES
260 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #142 background imageLoading...
Page #142 background image
-
140
-
Note (1) Thermostat operation is performed in A, B Block. When compressor and indoor fan stop by thermostat operation within 12 minutes from start, temperature
check is performed by operating indoor fan at speed 1 for 20 seconds before finishing 12 minutes and allowing decision of next operation block.
(c) DRY operation
After finishing start up operation described in (b) above, thermal dry operation is performed at 8 minutes intervals, according
to the difference between room temperature and thermostat setting temperature as shown below.
Beside, 1 cycle of this operating time consists of 8 minutes, 7 cycle operation is performed then.
(7) Outline of dehumidifying operation
(a) Choose the appropriate operation block area by the difference between room temperature and thermo-
stat setting temperature as shown below.
¡ Operation block area
(b) Start up operation
ON
OFF
OFF
0
3
6
912
ON
OFF
OFF
0
12
Compressor
and
outdoor fan
Set fan speed
Indoor fan
Start Temperature check
Start
Temperature check
Compressor
and
outdoor fan
Set fan speed
Indoor fan
Operation block decision
C.D Block
A.B Block
minutes
minutes
Speed 1Speed 1
20
seconds
ON
OFF
OFF
0
4
8
ON
OFF
OFF
0
8
Compressor
and
outdoor fan
Indoor fan
D Block
Compressor
and
outdoor fan
Indoor fan
C Block
Compressor
and
outdoor fan
Indoor fan
B Block
Compressor
and
outdoor fan
Indoor fan
A Block
20 seconds
20 seconds
minutes
minutes
Start Temperature check Start Temperature check
Operation block decision
20 seconds
minutes
minutes
Start Temperature check Temperature check
Operation block decision
Start
Speed 1
Speed 1
OFF
OFF
0
8
ON
OFF
OFF
0
3
8
Speed 1
Speed 1
Running time
Running start ~ 1 hour
1~2 hours
2 hours ~
Set temperature compensation
Set temperature +0.5
Set temperature +1.0
Set temperature +1.5
(d) ECONOMY operation ( ECONO button on the remote control : ON)
The set temperature changes as shown at right, and
the indoor unit fan speed is set on speed 2.
D Block C Block B Block A Block
20 +3
Room temp. Setting temp.(deg)

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi SRK13CES and is the answer not in the manual?

Mitsubishi SRK13CES Specifications

General IconGeneral
BrandMitsubishi
ModelSRK13CES
CategoryAir Conditioner
LanguageEnglish

Related product manuals