(12) Outline of fan operation
(a) Operation of major functional components
(13) Outline of clean operation
COOL,DRY,AUTO (COOL,DRY); after operation has stopped, the moisture inside the dryer air conditioner, controls the production of
fungus etc.
(a) Operating condition
Clean is switched ON, when the air conditioner receives a STOP signal.
(b) Detail of operation
(c) Reset condition
When control finishes 120 minutes after the Clean operation starts. When the stop signal is received from the remote controller.
(14) Outline of allergen clear operation
(a) The start fan operation, and decision to the operation pattern.
Indoor fan speed at 2nd speed, outdoor fan speed at 4th speed for 6 minutes, measure room temperature and outdoor temperature,
decide to use operation Pattern 1 or operation Pattern 2 according to the conditions in the following diagram.
(b) Operation flow
Inverter command speed
Indoor fan motor
Outdoor fan motor
Flap and louver
Speed 2 Speed 8
0rps
OFF
Depend on the flap and louver control
Speed 6 Speed 4 Speed 2Speed 2
AUTO HI MED LO ULO ECONO
Functional
components
Fan speed switching
Inverter command speed 0 rps
Indoor fan motor Speed 2
Outdoor fan motor OFF
Flap and louver Fully closed
0
20
4
Operation pattern2
Operation pattern1
Outdoor temperature (°C)
Room temperature (
°
C)
Inverter command speed 0
Indoor fan motor 2nd Speed
Outdoor fan motor 4th Speed
Flap and louver Horizontal, center
After cooling operation, if (outdoor
temperature-indoor temperature)
>
=
9°C or
humidity sensor measures humidity
>
=
70%
Fan operation2 (42 min.)
After cooling operation, if (outdoor
temperature-indoor temperature) < 9°C
and humidity sensor measures humidity
< 70%
Heating cycle operation (42 min.)
Operation pattern
2
Start
Allergen clear operations control (90 minutes)
End
Cooling
operation
(18 min.)
Standby
operation
(6 min.)
Complete stop Complete stop
Operation pattern1
Fan operation1
(18 min.)
Fan operation1
(84 min.)
Start fan
operation
(6 min.)