19
Error LED
Solid Red
Reverse polarity/
Reverse the battery
connections.
Error Reason/Solution
Error LED
Blinking Red
w/Cables Connected
Properly
The internal battery is too
hot/
Allow the unit to cool.
Bring the unit into cooler
environment.
Boost Light Does
Not Come On
w/Cables Connected
Properly
Connected battery is below
2 V/
Remove all loads, and
try again, or use Manual
Override Mode.
ERRORS
model no. 011-1906-4 contact us 1.888.942.6686
•Understanding Error Conditions:
The jump starter shall display an Error Condition when a
reverse polarity condition is present, a battery below two
(2) volts, or the internal battery overheating. When one
of these Error Conditions are present, the following will
happen:
•Charging the Jump Starter:
Connect the jump starter using the included USB charge
cable to the USB IN port. It can be recharged from any
USB powered port, like an AC adapter, car charger,
laptop and more. The USB IN port is rated at 2.1 Amps
to ensure safe and efficient charging of the internal lithium
battery. Due to FCC regulations, we recommend not to
charge and discharge the unit at the same time.

Other manuals for Motomaster Eliminator

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Motomaster Eliminator and is the answer not in the manual?

Motomaster Eliminator Specifications

General IconGeneral
BrandMotomaster
ModelEliminator
CategoryBattery Charger
LanguageEnglish

Related product manuals