Troubleshooting 41
8.9 (ODU)PC 0F(PFC module protection diagnosis and solution)
Description: Outdoor PCB detects PFC signal is low voltage or DC voltage is lower than 340V for 6s when quick check.
Recommended parts to prepare:
Connection wires
Outdoor PCB
Inductance
PFC circuit or IPM module board
Troubleshooting and repair:
PFC module protection
PFC module protection
Check whether the
connecting line between
main board and the PFC
module is connected tightly
Check whether the
connecting line between
main board and the PFC
module is connected tightly
Yes
Measure whether the voltage
between P and N is normal
refer to the Appendix
Measure whether the voltage
between P and N is normal
refer to the Appendix
No
Check whether the
inductance of PFC module is
good? If the inductance is
good, the resistance of the
two ports is 0
Check whether the
inductance of PFC module is
good? If the inductance is
good, the resistance of the
two ports is 0
Yes
Replace the inductance
Replace the inductanceNo
Connect it tightly, check
normal or not
Connect it tightly, check
normal or not
Replace the outdoor main board
Replace the outdoor main board
Yes
Yes
No
No
Replace the PFC module
Replace the PFC module
Trouble is solved
Trouble is solved

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the MrCool DIY-MULTI4-36HP230C and is the answer not in the manual?

MrCool DIY-MULTI4-36HP230C Specifications

General IconGeneral
BrandMrCool
ModelDIY-MULTI4-36HP230C
CategoryAir Conditioner
LanguageEnglish

Summary

Safety Precautions

Precautions

General safety guidelines and measures to prevent personal injury or unit damage.

Information servicing(For flammable materials)

Safety checks and procedures for working with flammable refrigerants.

Specifications

Electrical Wiring Diagrams

Wiring diagrams and component abbreviations for outdoor units.

Outdoor Unit Disassembly

Outdoor Unit Disassembly

Step-by-step guides for disassembling specific parts of the outdoor unit.

Troubleshooting

Safety Caution

Crucial safety warnings before performing any troubleshooting or maintenance.

General Troubleshooting

Common error codes for indoor and outdoor units and their basic solutions.

Quick Maintenance by Error Code

A table mapping error codes to likely faulty components for rapid replacement.

Troubleshooting by Error Code

Detailed troubleshooting steps and solutions for specific error codes (EH, EC, PC, etc.).

Check Procedures

Related product manuals