3-18
MS-6728 ATX Mainboard
RTC Alarm Date/Hour/Minute/Second
If Resume By Alarm is set to Enabled, the system will automatically resume
(boot up) on a specific date/hour/minute/second specified in these fields.
Available settings for each item are:
Alarm Date 01 ~ 31, Every Day
Alarm Hour 00 ~ 23
Alarm Minute 00 ~ 59
Alarm Second 00 ~ 59
Keyboard PowerOn Function
This controls how the PS/2 keyboard can power on the system. Settings:
Any Key, Specific Key, Disabled.
Specific Key for PowerOn
This setting allows users to set a password (max. 5 letters) for the
Keyboard Wakeup function.
Mouse PowerOn Function
This item allows the activity of the mouse to wake up the system sleep
state. Settings: Disabled, Any Action, Left-button, Right-button.
MSI Reminds You...
If you have changed this setting, you must let the system boot up
until it enters the operating system, before this function will work.