9. Technical data
8/
with magnet # 252 182.
9/ The IP rating is not part of the UL recognition.
10/ The conformity is fulfilled, assumed the wave guide of the sensor is embedded in an EMC-sealed and grounded housing.
11/ UL Recognition for RP and RH only.
Output
Interface EtherNet/IP™
Data transmission rate Max. 100 Mbit/s
Measured value Position, velocity / Option: Multi-position and multi-velocity measurement (max. 20 positions/velocities simultaneous)
Accuracy
Resolution 1…1000 µm selectable
Cycle time 1.0 ms up to 2000 mm, 2.0 ms up to 4800 mm, 3.0 ms up to 7620 mm, 4.0 ms up to 10060 mm stroke length
Linearity
7
< ±0.01% full stroke (minimum ±50 µm)
Repeatability < ±0.001% full stroke (minimum ±2.5 µm)
Hysteresis < 4 µm
Temperature coefficient < 15 ppm/°C
Operating conditions
Operating temperature −30…+85 °C (−22…+185 °F)
Humidity 90 % rel. humidity, no condensation
Ingress protection
8
RP: IP65 / RH: IP67 / RF: IP30 (IP67 when installed in pressure pipe) / RD4 electronics: IP67; RD4 sensor rod
type S: IP30, all other RD4 rod types: IP65
Shock test 100 g (single shock), IEC standard 68-2-27
Vibration test 15 g / 10…2000 Hz, IEC standard 68-2-6 (resonance frequencies excluded)
EMC test
Electromagnetic emission: EN 61000-6-4, CI SPR 16
Electromagnetic immunity: EN 61000-6-2, EN 61000-4-2/3/4/6, CE qualified
9
Magnet movement velocity Any
Design/Material
Sensor electronics housing Aluminum
RP Sensor profile Aluminum
RP stroke length 25…5080 mm (1…200 in.)
RH Sensor rod with flange Stainless steel 1.4301 / AISI 304
RH stroke length 25…7620 mm (1…300 in.)
RD4 Sensor rod with flange Stainless steel 1.4306 / AISI 304L
RD4 stroke length 25…5080 mm (1…200 in.)
RF Flexible sensor rod Stainless steel conduit with Teflon
®
coating
RF stroke length 100…10060 mm (4…396 in.)
Installation
Mounting position Any
Electrical connection
Connection type 2 × 4-pin (M12), 1 × 4-pin (M8) connector
Operating voltage
24 VDC (−15 / +20 %); UL Recognition requires an approved power supply with energy limitation
(UL 61010-1), or Class 2 rating according to the National Electrical Code (USA) / Canadian Electrical Code.
11
Ripple < 0.28 Vpp
Current consuption
110 mA typical for RH and RP models
(Note: Due to variations in cable length and topology as well as inrush current
draw on power up,
MTS recommends that 1 amp per sensor be available on the power supply used.)
Dielectric strength 500 VDC (DC ground to machine ground)
Polarity protection Up to −30 VDC
Over voltage protection Up to 36 VDC