EasyManuals Logo
Home>mycom>Air Compressor>200VMD

mycom 200VMD User Manual

Default Icon
161 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #26 background imageLoading...
Page #26 background image
2205Q2JE-HO-S6-N_2020.01.
Chapter 2 Compressor Specifications and Structure
SCV-series Screw Compressors 2.3 Compressor Specifications
2-4
Table 2-2 Standard Specifications of SCV-series 200V**
Item
200
VLD
VMD
VSD
VLG
VMG
VSG
Working fluid (Refrigerant)
Ammonia, Hydro Fluoro Carbon and Other
Mass of compressor alone
kg
700
670
630
680
650
610
Capacity control (Actual load)
%
10 to 100
Rotation direction
CCW viewed from motor
Swept volume
@ 3550 min
-1
m
3
/h
1460
1220
975
1460
1220
975
@ 2950 min
-1
m
3
/h
1210
1020
810
1210
1020
810
Connected pipe size
Gas inlet port
MYK 150A
Gas outlet port
MYK 125CD
MYK 125A
Main oil supply port (Journal)
MYK 20A
Oil supply port for side bearing of F rotor
Rc3/8
Oil injection port
Rc1/2
Economizer port
MYK 32A
Liquid injection port 1
MYK 25A
Liquid injection port 2
Rc1/2
Capacity control
decrease (unload)
Rc3/8
increase (load)
Rc3/8
Oil drain
Rc1/2
Note 1: Unless otherwise noted, the pressure unit MPa represents the gauge pressure in this manual.
Note 2: MYK flange is the standard flange for MYCOM single screw compressor.
Table 2-3 Standard Specifications of SCV-series 250V*D
Item
250
VLLD
VLD
VMD
VSD
Working fluid (Refrigerant)
Ammonia, Hydro Fluoro Carbon and Other
Mass of compressor alone
kg
1390 1300 1220 1180
Capacity control (Actual load)
%
10 to 100
Rotation direction
CCW viewed from motor
Swept volume
@ 3550 min
-1
m
3
/h
3370 2840 2380 1900
@ 2950 min
-1
m
3
/h
2800 2360 1980 1580
Connected pipe size
Gas inlet port
MYK 250A
Gas outlet port
MYK 150CD
Main oil supply port (Journal)
MYK 25A
Oil supply port for side bearing of F rotor
Rc3/8
Oil injection port
Rc1/2
Economizer port
MYK 50A
Liquid injection port 1
MYK 32A
Liquid injection port 2
Rc1/2
Capacity control
decrease (unload)
Rc3/8
increase
(load)
Rc1/2
Oil drain
Rc1/2
Note 1: Unless otherwise noted, the pressure unit MPa represents the gauge pressure in this manual.
Note 2: MYK flange is the standard flange for MYCOM single screw compressor.