CALIBRATION PROCEDURE
NI PXIe-4113
Dual-Output Programmable DC Power Supply
This document contains the verification and adjustment procedures for the NI PXIe-4113
(NI 4113). Refer to ni.com/calibration for more information about calibration solutions.
Contents
Required Software.....................................................................................................................1
Related Documentation.............................................................................................................2
Password................................................................................................................................... 2
Calibration Interval................................................................................................................... 2
Test Equipment..........................................................................................................................2
Test Conditions..........................................................................................................................3
Calibration Overview................................................................................................................4
Verification................................................................................................................................5
Voltage Output and Measurement..................................................................................... 5
Current Output and Measurement.....................................................................................7
Load Regulation................................................................................................................9
Remote Sense..................................................................................................................12
Adjustment.............................................................................................................................. 13
Adjusted Specifications...................................................................................................13
Initiating the Adjustment Session................................................................................... 14
Connecting and Configuring Equipment for Voltage Adjustment..................................14
Adjusting Voltage Output and Measurement.................................................................. 14
Connecting and Configuring Equipment for Current Adjustment..................................15
Adjusting Current Output and Measurement.................................................................. 16
Closing the Adjustment Session..................................................................................... 17
Reverification..........................................................................................................................17
Worldwide Support and Services............................................................................................ 17
Required Software
Calibrating the NI 4113 requires you to install the following software on the calibration
system:
NI-DCPower 15.1 or later.
Supported application development environment (ADE)—LabVIEW or
LabWindows
/CVI
.
Supported operating system—Windows.

Other manuals for National Instruments NI PXIe-4112

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the National Instruments NI PXIe-4112 and is the answer not in the manual?

National Instruments NI PXIe-4112 Specifications

General IconGeneral
BrandNational Instruments
ModelNI PXIe-4112
CategoryPower Supply
LanguageEnglish

Related product manuals