UsingtheCFGRESETSwitchatPower-On
Intheeventyouforgetthenetworkconfigurationthataparticularserial
ENETinterfaceisusing,youcanresettheunittoitsdefaultnetwork
characteristics.BypressingandholdingtheCFGRESETswitchwhile
youpowerontheserialENETinterface,thenetworkparametersrevertto
thedefaultsettingsasdefinedonthebaseplatelabel.
Youmustpressandholdtheswitchforapproximatelythreesecondsuntil
thePWR/RDYLEDbecomessolidred.Ifyoureleasetheswitchpriorto
threeseconds,nochangeoccurstothenetworkconfiguration,andthe
serialENETinterfacecontinuestobootnormally.
ThePWR/RDYLEDgoesthroughthefollowingchangesduringthese
threeseconds:
1. TheLEDbeginsslowlyalternatingbetweenredandyellow.
2. Thealternatingpatternincreasesintempo.
3. Atthreeseconds,thePWR/RDYLEDbecomessteadyred.This
indicatesthenetworkconfigurationwillbesettothefactory
defaultsettings.
4. WhenyoureleasetheCFGRESETswitch,theboxcontinuesto
bootasnormal,andthePWR/RDYLEDindicatestheboot
processasdescribedinENETLEDDescriptions.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the National Instruments PCI-8430 and is the answer not in the manual?

National Instruments PCI-8430 Specifications

General IconGeneral
BrandNational Instruments
ModelPCI-8430
CategoryComputer Hardware
LanguageEnglish

Related product manuals