SANDSTORM
SINGLE-/DOUBLE-CHAMBER USER MANUAL
19
TROUBLESHOOTING
ATTENTION
Single-chamber only
Before filling the tanks with media, fill each tank with water up to a third of its height with a hose
through the filling port before media filling.
10.
Fill the tanks with media through the filling port. Fill each tank up to the media level marker on the filter tank.
*Crushed basalt.
Tank diameter
(inch)
Sand quantity*
kg lbs
12 60 132
16 90 198
20 120 265
24 180 397
30 240 529
36 360 794
48 575 1768
Tank diameter
(inch)
Sand quantity*
kg lbs
30 270 595
36 350 770
48 675 1490
Single-chamber Double-chamber
11.
Flatten the surface of the media.
12.
Make sure that the filling port and its gasket are clear of any remaining gravel particles and close the
filling port.
13.
Turn on the water and start irrigation.
(See tank replacement parts: single-chamber - page 20, double-chamber - page 22).
For further assistance, contact your local Netafim™ representative.

Other manuals for Netafim SANDSTORM

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Netafim SANDSTORM and is the answer not in the manual?

Netafim SANDSTORM Specifications

General IconGeneral
BrandNetafim
ModelSANDSTORM
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals