30 | ni.com | GPIB Hardware Installation Guide and Specifications
Environment
Operating ambient temperature 0 °C to 55 °C
(Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2.)
Operating relative humidity 10% to 90%, noncondensing
(Tested in accordance with IEC 60068-2-56.)
Storage ambient temperature -40 °C to 70 °C
(Tested in accordance with IEC 60068-2-1 and
IEC 60068-2-2.)
Storage relative humidity 5% to 95%, noncondensing
(Tested in accordance with IEC 60068-2-56.)
Shock and Vibration
Operating shock 30 g peak, half-sine, 11 ms pulse
(Tested in accordance with IEC 60068-2-27;
test profile developed in accordance with
MIL-PRF-28800F.)
Random vibration
Operating 5 Hz to 500 Hz, 0.31 g
rms
Nonoperating 5 Hz to 500 Hz, 2.46 g
rms
(Tested in accordance with IEC 60068-2-64.
Nonoperating test profile exceeds the
requirements of MIL-PRF-28800F, Class 3.)
PXI-GPIB
Performance
GPIB
3-wire up to 1536 kbytes/s
HS488 up to 7885 kbytes/s
Power Requirements
+5 V 80 mA, Typical
165 mA, Maximum
VIO 3 mA, Typical
10 mA, Maximum