English – 5
EN
OPERATION
7
Basic Operation
You can use remote controller or manual control switch to
“Open”, “Close” and “Stop” the curtain.
The motor will stop when the system finishes the open or close
curtain functions.
If you want to stop the curtain at any position on the rail, just
push “Stop” button when the curtain reaches the position you
want.
In case of power off, the curtain still can be open or closed ma-
nually. In standby mode, you can pull the curtain to start the sy-
stem.
FAQ
8
Issue Possible Causes Solutions
Motor no response Power supply failure Check if AC power supply connection is ok.
Curtain can’t be closed
completely
Curtain goes on the opposite direction of your
command
Use remote controller to send “Swap” com-
mand
Limits data error Power off the system for more than 15s.
Manual control switch
don’t work
Bad connection of signal cable Check if the cable is ok and the connection of
cable is correct
Can’t controlled by remote
controller
The remote controller is not memorized Memorize the remote controller
Low battery of remote controller Replace the battery with a new one
Control distance is too far Come closer to the motor
Curtain stops before rea-
ching limits
Limits setting not correct Initialize the limits
Curtain is too heavy Check if the weight of curtain is out of speci-
cation
Curtain stopped by something Check the rails and accessories
Others Power off the system for 1 minute to reset the system. If still not ok, contact your distributor.
WARRANTY
9
2.5 years free warranty after sale date, without intentional destroy and unauthorized disassembly.
Hints
1. After powered on, the indicator on motor will on for 1s.When
the indicator is off, the motor is ready for taking control si-
gnals.
2. Each time the indicator on motor will flash once, when a va-
lid signal is received.
3. Memorize the remote controller to the motor before using it
to control the motor.
Hand Start Function
The curtain system has hand start function. In standby mode,
you can pull the curtain to start the system.