Technical characteristics ROBUS
Model type
RB400 RB600 / RB600P RB1000 / RB1000P RB250HS RB500HS
Type Electromechanical gearmotor for the automatic movement of sliding gates for residential use, com-
plete with electronic control unit
Pinion Z15m4 Z15m4 Z15m4 Z15m4 Z18m4
Maximum frequency of ope-
rating cycles (nominal torque)
80 cycles per day
(the control unit
allows up to the
maximum descri-
bed in table 2)
100 cycles per
day (the control
unit allows up
to the maximum
described in table
2)
150 cycles per day
(the control unit
allows up to the
maximum described
in table 2)
80 cycles per
day (the control
unit allows up
to the maximum
described in
table 2)
100 cycles per
day (the control
unit allows up
to the maximum
described in
table 2)
Maximum continuous opera-
ting time (nominal torque)
7 minutes
(the control unit
allows up to the
maximum descri-
bed in table 2)
7 minutes
(the control unit
allows up to the
maximum descri-
bed in table 2)
5 minutes
(the control unit
allows up to the
maximum described
in table 2)
6 minutes
(the control unit
allows up to
the maximum
described in
table 2)
6 minutes
(the control unit
allows up to
the maximum
described in
table 2)
Application limits ROBUS is generally able to automate gates up to the weight and length limits given in table 2
Durability Estimated between 20,000 and 250,000 cycles, depending on the conditions given in Table 2
Power input 230Vac (+10% -15%) 50/60Hz.
Thrust maximum absorbed
power [equivalent to amperes]
330W [2A]
[3.9A version /V1]
515W [2.5A]
[4.8A version /V1]
450W [2.3A]
[4.4A version /V1]
330W [2A]
[3.9A version /V1]
330W [2.5A]
[4.8A version /V1]
Insulation class 1 (a safety grounding system is required)
Emergency power supply With PS124 optional accessory
Flasher output For 2 LUCYB flashing lights (12V, 21 W lamp)
Open Gate Indicator Output For one 24V maximum 4W bulb (the output voltage may vary between –30 and +50% and can also
control small relays)
BLUEBUS output One output with a maximum load of 15 BLUEBUS units
STOP input Fornormallyclosedornormallyopencontacts,for8.2kΩconstantresistance;withself-recognition
(any variation from the memorized status causes the “STOP” command)
Step-by-step Input For normally open contacts (the closing of the contact causes the “STEP-BY-STEP” command)
OPEN input For normally open contacts (the closing of the contact causes the “OPEN” command)
CLOSE input For normally open contacts (the closing of the contact causes the “CLOSE” command)
Radio connector “SM” connector for SMXI and SMXIS receivers
Radio AERIAL Input 52ΩforRG58orsimilartypeofcable
Programmable functions 8 ON-OFF functions and 8 adjustable functions (see tables 5 and 7)
Self-Recognition functions Automatic identification of devices connected with the BLUEBUS outlet
Self-recognitionofthetypeof“STOP”device(NormallyOpen,NormallyClosedcontactor8.2kΩ
fixed resistor)
Self-recognition of the gate length and calculation of the deceleration points and the partial opening
point.
Use in acid, saline or poten-
tially explosive atmosphere
No No No No No