11 Main technical Data
Type
C 125.4
C 130.2
C-PG 130.2 X-TRA
Electric specifications
Rated voltage V 230-240 230-240
Rated frequency Hz 50 50
Rated power consumption kW 1.7 1.8
Current A 7.5 7.8
Protection class
Class I/
Class II
Class II Class II
Protection degree IP xx IPX5 IPX5
Hydraulic specifications
Rated pressure MPa/bar 10.0/100 10.5/105
Max. pressure MPa/bar 12.5/125 13.0/130
Rated water flow l/min/l/h 5.8/350 5.8/350
Max. water flow l/min/l/h 8.7/520 8.7/520
Max. water inlet pressure Mpa/bar 1/10 1/10
0
Max. water inlet temperature °C 40 40
Max. water inlet temp. suction mode °C 20 20
Weight kg 9.0
9.3 (C 130.2)
10.1 (C-PG 130.2 X-TRA)
Hand-arm vibration according to ISO
5349-1:
Standard nozzle
m/s
2
< 2.5 ±1 < 2.5 ±1
Sound pressure level LpA in accord-
ance with ISO 3744
dB(A) 77.2 ±2 77.2 ±2
Guaranteed sound power level LWA
in accordance with 2000/14/EC
dB(A) 92 92
We reserve the right to make alterations.