Test J, Will Not Run On DC Power
NOR000959A
Check for blown fuse in DC circuit.
NO
Is fuse
blown?
Replace fuse.
YES
Recharge or replace battery.
Check that the wiring to the refrigerator
is at least #12 gauge wire (required).
NO
Is wiring at
least #12
gauge?
Refer to the Installation Manual for
the recommended wire size.
YES
Check DC voltage at control module.
NO
Is voltage
below 10.4
VDC?
Correct high resistance (voltage drop) in
supply circuit.
YES
Troubleshooting Symptoms, cont’d.
22
www.norcold.com N8DCX, N10DCX Models