Fault Code - "E1"
Is
thermistor
wire
connected?
Correct connection.
NO
Make sure thermistor in the fresh food
compartment is connected.
Remove thermistor cover in fresh food
compartment and check connection of
thermistor wire to thermistor.
YES
Complete the “Diagnostic Pre-Checks.”
Is
thermistor
wire
connected?
Correct connection.
NO
YES
Check connection of thermistor wire to
the refrigerator electronic controls.
Refer to the wiring diagram.
Replace Thermistor.
NOR000978A
E1
Possible Cause:
The fresh food thermistor is not
cycling properly.
Troubleshoot Electronic Controls Fault Codes
Fig. 5 - Mode Button will display Electronic Controls Fault Codes
24
www.norcold.com N8DCX, N10DCX Models