5
A22LK
Ordering Information
Switch
List of Models (Completely Assembled) ... Shipped as a set which includes the Operation Unit and Switch Unit. For
the model with Operation Unit only, contact your OMRON
representative.
* Lock and release type are Solenoid lock and Mechanical release.
Specifications
Certified Standards
Note:
Only models with NC contacts have a direct opening mechanism.
Certified Standard Ratings
TÜV (EN60947-5-1)
Note:
Use a 10 A fuse type gI or gG that conforms to IEC60269 as a
short-circuit protection device. This fuse is not built into the Switch.
Solenoid Coil Characteristics
Characteristics
Note: 1. Do not allow the load current to exceed the rated value.
2. The contact ON/OFF timing is not synchronized. Confirm
performance before application.
3. Once the contacts have been used to switch a load,
however, they cannot be used to switch smaller loads. The
contact surfaces will become rough once they have been
used and contact reliability for smaller loads may be
reduced.
*1. Malfunction within 1 ms.
*2. With no icing or condensation.
*3. The degree of protection from the front of the panel.
Appearance
Key release
position
Key position of
NC contact
closing
Lock
position *
Contact Configuration
Key
availability
Model
1NC/1NO+1NC/1NO Yes A22LK-2RLA-22-K01-SJ
1NC/1NO+1NC/1NO
Yes
A22LK-2RLB-22-K01-SJ
1NC/1NO+1NC/1NO
No
A22LK-2RLA-22-01-SJ
1NC/1NO+1NC/1NO
No
A22LK-2RLB-22-01-SJ
Certification
body
Standards File No.
UL
UL508, CSA C22.2
No.14
E76675
TÜV SÜD
EN60947-5-1
(certified direct
opening)
Consult your OMRON
representative for
details.
CQC(CCC) GB140485
Consult your OMRON
representative for
details.
KOSHA KS C IEC 60947-5-1
Consult your OMRON
representative for
details.
Item Utilization category AC-15 DC-13
Rated operating current (Ie) 3A 0.27A
Rated operating voltage (Ue) 240V 250V
Item Type 24 VDC
Rated operating voltage (100% ED) 24 VDC ±10%
Current consumption Approx. 88mA
Insulation Class A (130°C max.)
Item Model A22LK
Allowable
operating
frequency
Mechanical 30 operations/minute max.
Electrical 30 operations/minute max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Dielectric
strength
Between terminals
of same polarity
2,500 VAC, 50/60Hz for
1min.
Between each
terminal and ground
6,000 VAC, 50/60Hz for
1min.
Vibration resistance *1
10 to 55 Hz, 1.5mm double
amplitude (within 1 ms)
Shock
resistance
Destruction 1000m/s
2
Malfunction *1 300m/s
2
Durability
Mechanical 100,000 operations min.
Electrical 100,000 operations min.
Ambient operating temperature *2 -10 to +55°C
Ambient operating humidity 35% to 85%RH
Degree of protection *3 IP65 *3
Electric shock protection class Class II
Degree of contamination 3 (EN60947-5-1)