EasyManuals Logo
Home>Omron>Blood Pressure Monitor>BP652

Omron BP652 User Manual

Omron BP652
39 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #31 background imageLoading...
Page #31 background image
31
GUIDANCE AND MANUFACTURER’S DECLARATION
OMRON Wrist Blood Pressure Monitor (BPM)
Information for accompanying documents in the scope of IEC60601-1-2:2007
Important information regarding Electro Magnetic Compatibility (EMC)
With the increased number of electronic devices such as PC’s and mobile
(cellular) telephones, medical devices in use may be susceptible to
electromagnetic interference from other devices. Electromagnetic interference
may result in incorrect operation of the medical device and create a potentially
unsafe situation. Medical devices should also not interfere with other devices.
In order to regulate the requirements for EMC (Electro Magnetic Compatibil-
ity) with the aim to prevent unsafe product situations, the IEC60601-1-2
standard has been implemented. This standard defines the levels of immunity
to electromagnetic interferences as well as maximum levels of electromagnetic
emissions for medical devices.
Medical devices manufactured by OMRON Healthcare conform to this
IEC60601-1-2:2007 standard for both immunity and emissions.
Nevertheless, special precautions need to be observed:
The use of accessories and cables other than those specified by OMRON,
with the exception of cables sold by OMRON as replacement parts for
internal components, may result in increased emission or decreased
immunity of the device.
The medical devices should not be used adjacent to or stacked with other
equipment.
In case adjacent or stacked use is necessary, the medical device should be
observed to verify normal operation in the configuration in which it will be
used.
Refer to further guidance below regarding the EMC environment in which
the device should be used.
The MEDICAL ELECTRICAL EQUIPMENT BPM needs special
precautions regarding EMC and needs to be installed and put into service
according to the EMC information provided in this documentations.
The Essential Performance of the BPM is to measure a blood
pressure and a pulse rate and using the memory function.
The BPM may be interfered with by other equipment, even if that other
equipment complies with CISPR EMISSION requirements.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron BP652 and is the answer not in the manual?

Omron BP652 Specifications

General IconGeneral
TypeAutomatic
Number of users1 user(s)
Placement supportedWrist
Pulse rate measuringYes
Mean arterial pressure-
Battery typeAAA
Battery voltage1.5 V
Number of batteries supported2
Display typeLCD
Weight and Dimensions IconWeight and Dimensions
Depth21 mm
Width70 mm

Related product manuals