D2F
D2F
199
Characteristics
Operating speed 1 to 500 mm/s (pin plunger models)
Operating frequency Mechanical: 200 operations/min max.
Electrical: 30 operations/min max.
Insulation resistance 100 MΩ min. (at 500 VDC)
Contact resistance
(initial value)
D2F models: 30 mΩ max.
D2F-F models: 50 mΩ max.
D2F-01 models: 100 mΩ max.
Dielectric strength (see note 2) 600 VAC, 50/60 Hz for 1 min between terminals of the same polarity
1,500 VAC, 50/60 Hz for 1 min between current-carrying metal parts and ground, and between
each terminal and non-current-carrying metal part
Vibration resistance
(see note 3)
Malfunction: 10 to 55 Hz, 1.5-mm double amplitude
Shock resistance
(see note 3)
Destruction: 1,000 m/s
2
{approx. 100G} max.
Malfunction: 300 m/s
2
{approx. 30G} max.
Durability (see note 4) Mechanical: 1,000,000 operations min. (60 operations/min) (Refer to Engineering Data.)
Electrical: 30,000 operations min. (30 operations/min) (Refer to Engineering Data.)
Degree of protection IEC IP40
Degree of protection against
electric shock
Class I
Proof tracking index (PTI) 175
Ambient operating
temperature
–25°C to 65°C (at ambient humidity of 60% max.) (with no icing)
Ambient operating humidity 85% max. (for 5°C to 35°C)
Weight Approx. 0.5 g (pin plunger models)
Note: 1. The data given above are initial values.
2. The dielectric strength shown in the table indicates a value for models with a Separator.
3. For the pin plunger models, the values are at the free position and total travel position. For the lever models, they are at the total
travel position.
4. For testing conditions, consult your OMRON sales representative.
Approved Standards
Consult your OMRON sales representative for specific models with
standard approvals.
UL1054 (File No. 41515)/
CSA C22.2 No. 55 (LR21642)
Rated
voltage
D2F (general-
purpose)
D2F (low
operating
force)
D2F-01
125 VAC 3 A 1 A ---
30 VDC 2 A 0.5 A 0.1 A
Contact Specifications
Item D2F models D2F-01 models
Contact
Specification Crossbar
Material Silver alloy Gold alloy
Gap
(standard
value)
0.25 mm
Minimum applicable load
(see note)
100 mA
at 5 VDC
1 mA at 5 VDC
Note: For more information on the minimum applicable load,
refer to Using Micro Loads on page 202.
Contact Form
SPDT