4
H5CRH5CR
Nomenclature
■ Factory Settings
The following table shows the timer settings when it is shipped. Please change the settings as necessary to suit the system before opera-
tion. Settings and the display receive power from the internal battery and are therefore unaffected by external power interruptions.
Note: With the initial settings, there will be no output even if the power supply is connected. External inputs and outputs cannot be used
without a power supply.
1. Power indicator
2. Signal input indicator
3. Reset indicator
4. Gate indicator
(not included in the H5CR-L)
5. Key protection indicator
(not included in the H5CR-L)
6. Control output indicator
7. Present value
(character height: 8 mm)
(Non-significant zeroes suppressed)
8. Set value
(character height: 4 mm)
(Indicates value in set function mode)
9. Mode indicator
10. Timing indicator
Display
11. Increment keys (1 to 4)
(Used to change the corresponding
digit of the set value. Used to change
data in the set mode.)
12. Display key
(Switches to the present value display.)
Operation key
13. Mode key
(Switches from run mode to set mode.
Changes items in the set mode.
14. Reset key
(Resets timing and outputs.)
2
3
4
5
10
1213
14
9
1
7
11
6
8
Model H5CR-B (Standard)/H5CR-S (Short body) H5CR-L (Basic)
Time range - -. - -s
Present value 0.00 s
Presets 0.00 s
UP/DOWN mode UP
Output mode A: Signal on delay (I)
Output time Sustained
Input signal time 20 ms
Key protect level KP-1 ---