EasyManuals Logo
Home>Omron>Timer>H5CR

Omron H5CR Manual

Omron H5CR
15 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
H5CR H5CR
3
Part number H5CR-L H5CR-B H5CR-S
Inputs Types available Reset and start signal Reset, gate, start signal, and key protect
Signal, Type No-voltage input
reset ON impedance 1 k max. (Approx. 2 mA when 0)
and gate Residual voltage 2 V max. in ON state
OFF impedance 100 k minimum
Pulse width 1 ms or 20 ms selectable for reset and signal
20 ms for gate
Key Type No-voltage input
protect ON impedance 100 k max. (Approx. 2 mA when 0)
Residual voltage 1 V max. in ON state
OFF impedance 100 k minimum
Response time 1 second
Type Time limit SPDT relay output or NPN open collector transistor output (H5CR-S)
Instantaneous
Relay Max. load 5 A, 250 VAC resistive load (p.f. = 1)
Min. load 10 mA, 5 VDC
Solid- Max. load 100 mA, 30 VDC
state Residual voltage 2 V max., 1 V typical
Repeat accuracy Power start ±0.01%, ±0.05 second max.
Signal start ±0.005%, ±0.03 second max. (rate for set value)
Setting error
Resetting system Power reset (A, A-1, A-2, B, D and E modes)
External, manual, automatic resets (may be internal depending on A-1, B, B-1, D and E
operation modes)
Resetting time Power reset 0.5 second minimum (A, A-1, A-2, B, D and E modes)
Indicators 4-digit LCD alphanumeric 4-digit LCD alphanumeric display with backlighting
display without backlighting 8 mm (0.32 in) H present value, 4 mm (0.16 in) H set value
8 mm (0.32 in) H present
value, 4 mm (0.16 in) H
set value
Memory function Retains preset values for 10 years at 25° C (77° F)
Materials Plastic case
Mounting Panel or surface; Y92F-30 Panel, Y92F-30 mounting bracket included
mounting bracket not
included
Connections 8-pin round socket Screw terminals
Weight 105 g (3.7 oz.) 160 g (5.6 oz.) 120 g (4.2 oz.)
Approvals UL/CSA/SEV/CE
Operating ambient temperature -10° to 55°C (14° to 131°F) with no icing
Humidity 35% to 85% RH
Vibration Mechanical durability 10 to 55 Hz with 0.75 mm single amplitude in 3 directions
Malfunction durability 10 to 55 Hz with 0.5 mm single amplitude in 3 directions
Shock Mechanical durability 30 G each in three directions
Malfunction durability 10 G each in three directions
Variation due to voltage change Included in "Repeat accuracy" specification
Variation due to temperature change Included in "Repeat accuracy" specification
Insulation resistance 100 M min. at 500 VDC between current-carrying terminal and exposed non-current-
carrying metal parts, and between non-continuous contacts.
Dielectric strength 2,000 VAC, 50/60 Hz for 1 minute between current-carrying terminal and exposed
non-current-carrying metal parts for 100 to 240 VAC type
1,000 VAC for both 24 VAC and 12 to 24 VDC types
Mechanical 10 million operations minimum
Electrical 100,000 operations minimum at 5 A, 240 VAC, resistive load (p.f. = 1)
Control
output
SPECIFICATIONS continued
Service life
(SPDT relay)

Other manuals for Omron H5CR

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron H5CR and is the answer not in the manual?

Omron H5CR Specifications

General IconGeneral
BrandOmron
ModelH5CR
CategoryTimer
LanguageEnglish

Related product manuals