3-6
COLD TEMPERATURE OPERATION
Drain the heat exchanger (p. 4-8) and muffler be-
fore cold weather sets in if the genset is not being
used. Freezing water can damage the muffler and
the raw water tubes in the heat exchanger.
CARE OF NEW OR RE-BUILT ENGINE
Avoid no-load operation as much as possible during
break-in. Change the oil and oil filter after the first 50
hours of operation (p. 4-3).
EXERCISING THE GENSET
Exercise the genset at least 1 hour every month if
use is infrequent. Run the genset at 1/4 to 3/4 load.
A single exercise period is better than several short-
er periods. Exercising a genset drives off moisture,
re-lubricates the engine, uses up fuel before it be-
comes stale and removes oxides from electrical
contacts. The result is better starting, more reliable
operation and longer engine life.
STORING THE GENSET
Proper storage is essential for preserving top gen-
set performance and reliability when the genset
cannot be exercised regularly and will be idle for
more than 120 days.
Storing the Genset
1. Turn off the genset line circuit breaker.
2. Change the engine oil and filter and attach a tag
indicating oil viscosity. See ENGINE OIL REC-
OMMENDATIONS (p. 3-1).
3. Crank the engine several revolutions but do not
let it start. This will fill the oil passages with the
new oil.
4. Disconnect the battery cables (negative []
cable first) from the starting battery and store
the battery according to the battery manufac-
turer’s recommendations. See MAINTAINING
THE BATTERY AND BATTERY CONNEC-
TIONS (p. 4-2).
5. Check coolant level and add as necessary
(p. 4-7). Test the coolant mixture if freezing
temperatures are possible and change if nec-
essary.
WARNING
Hot coolant is under pressure
and can cause severe burns when loosen-
ing the pressure cap. Let the engine cool
before loosening the pressure cap.
6. Drain the heat exchanger and muffler if freezing
temperatures are expected.
7. Disengage a PTO clutch if so equipped.
8. Clean and lightly oil parts that can rust.
Returning the Genset to Service
1. Check the oil tag on the genset and change the
oil if the viscosity indicated is not appropriate for
the temperatures expected. See ENGINE OIL
RECOMMENDATIONS (p. 3-1).
2. Reconnect the starting battery (negative []
cable last). See MAINTAINING THE BATTERY
AND BATTERY CONNECTIONS (p. 4-2).
3. Replace the raw water pump impeller if it was
installed more than a year ago (p. 4-12).
4. Perform the maintenance required (p. 4-1),
conduct the pre-start checks and prime the fuel
system.
5. Start and run the genset.
6. Turn on the genset line circuit breaker when
ready to power loads.
Redistribution or publication of this document,
by any means, is strictly prohibited.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Onan MDKBP and is the answer not in the manual?

Onan MDKBP Specifications

General IconGeneral
BrandOnan
ModelMDKBP
CategoryPortable Generator
LanguageEnglish

Related product manuals