50
Issue: Water pump is running when all faucets & valves are closed
Troubleshoot: Leak in the system. Identify leaking fitting and attempt to tighten the fitting (usually hand-tight should be
sufficient without the need for a wrench which could potentially over-tighten and damage the system. If still leaking, dis-
connect and check for debris or degrading within the fitting.
Issue: Water pump running but no water at faucets
Troubleshoot: No water in tanks? Check for faulty sensor that could be misleading you to think that there is water in the
tanks. Possibly the sensor needs cleaning or replacing.
Check the tank selector valve is directed at the correct tank (or both tanks are chosen).
Issue: Stove top won’t stay ignited
Troubleshoot: Press and hold the ignition/ dial for 10 seconds to overcome the safety thermocouple.
Consider the outside temperature; cold weather can cause the BTU of propane to drop. This can impact overall perfor-
mance of the propane system. Keep your propane tanks full during cold weather and check other appliances that might
also be using propane at the time.
troubleshooting
water tanks - troubleshooting
PROPANE SYSTEM - troubleshooting