10
ENGLISH
Maintenance
continued
To reassemble, check O-ring on tube, and replace if damaged. Replace tube by
rst lining up slot at base of tube with tab inside fan housing.
Insert tube and push down until the tube is seated. Make sure O-ring is in place
against fan housing opening. Replace and tighten collar until collar locking
tabs are locked in place. Reattach bag spring.
Many times blockage occurs due to a full disposable inner bag causing dirt to
back down the air ow system. When that happens, the blockage will be at the
top of the system, starting in the area where the disposable inner bag connects
to the deector.
5
5
7
6
7
6
Motor Protection/Vacuum Shutdown
If the vacuum becomes overloaded, which could occur by sucking up a large obstruction or on
extremely thick carpet, the electronics are designed to shut down the vacuum. If this happens,
the vacuum will be turned off but the headlights will remain on. To reset the vacuum turn the
unit off, wait 5 seconds, and then turn it back on. If it shuts down again there may be a large
obstruction in the vacuum.
Note: If the above actions do not correct the problem, contact an Oreck authorized service
center or call the customer service center. US: 1-800-989-3535 Canada: 1-888-676-7325