8.5. Random Auto Restart Control
If there is a power failure during air conditioner operation, operation will be automatically restarted after 3 to 4 minutes when the
power is resumed. It will start with previous operation mode and airflow direction.
Restart time is decided randomly using 4 parameter:
Intake air temperature, setting temperature, fan speed and Air Swing Blade position.
Random Auto Restart Control is not available when Timer is set.
This control can be omitted by open the circuit of JX2. (Refer Circuit Diagram)
8.6. Delay ON Timer Control
When the Delayed ON Timer is set by using the remote control, the unit will start operate slightly before the set time, so that
the room will reach nearly to the set temperature by the desired time.
For Cooling and Soft Dry mode, the operation will start 15 minutes before the set time.
For Heating mode, the operation will start 30 minutes before the set time.
For Automatic mode, the indoor fan will operate at SLo speed for 25 seconds, 30 minutes before the set time to detect the
intake air temperature to determine the operation mode. The operation indication lamp will blink at this time.
8.7. Remote Control Signal Receiving Sound
Long beep sound will be heard when:-
Stopping the Air Conditioner using ON/OFF switch.
Stopping the Quiet Mode.
Stopping the Powerful Mode.
Stopping the Ion Mode.
Short beep sound will be heard for others.
To switch off the beep sound:-
Press the Automatic Operation Button continuously for 10 seconds or more (beep”“beep will be heard at the 10th second).
Repeat the above if you want to switch ON the beep sound.
However, if the Automatic Operation Button has been pressed the Automatic operation will be activated.
If you do not require this operation, you may change it by using the remote control.
8.8. Indoor Fan Speed Control
Auto Fan Speed Control
When set to Auto Fan Speed, the fan speed is shifted automatically between Stop to SHi depend on each operation as shown
below.
Manual Fan Speed Control
Basic fan speed adjustment (3 settings, from Lo to Hi) can be carried out by using the Fan Speed selection button at the remote
control.
30
CS-A7CKP CU-A7CKP5 / CS-A9CKP CU-A9CKP5 / CS-A12CKP CU-A12CKP5

Other manuals for Panasonic CS-A12CKP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-A12CKP and is the answer not in the manual?

Panasonic CS-A12CKP Specifications

General IconGeneral
BrandPanasonic
ModelCS-A12CKP
CategoryAir Conditioner
LanguageEnglish

Related product manuals