EasyManuals Logo
Home>Panasonic>Air Conditioner>CS-A12CKP

Panasonic CS-A12CKP Service Manual

Panasonic CS-A12CKP
90 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #4 background imageLoading...
Page #4 background image
Indoor Unit
Random Auto Restart Control
Operation is restarted randomly after power
failure at previous setting mode.
Anti-Freezing Control
Anti-Freezing control for indoor heat
exchanger. (Cooling and Soft Dry)
Ionizer Control
Ionizer control for generate negative ion in
discharge air.
Indoor Fan Speed Control
High, Medium and Low.
Automatic Fan Speed Mode
Heating : Fan speed varies from Me
SSLo in accordance with
indoor heat exchanger.
Cooling : Fan rotates at Hi, Me and SLo
speed. Deodorizing control is
available.
Soft Dry : Fan rotates at Lo- speed.
Deodorizing control is
available.
Automatic air swing and manual adjusted
by remote control for vertical airflow.
Manually adjusted by hand for horizontal
airflow.
Airflow Direction Control
Automatic Operation Button
Press for < 5s to operate Automatic
operation mode.
(Used when the remote control cannot be used.)
Press continuously for 5s or < 10s to
operate Test Run/Pump down. Beep
sound will be heard at the 5th second.
(Used when test running or servicing.)
Press continuously for 10s and above to
omit or resume the remote control signal
receiving sound. Beep, beep sound will
be heard at the 10th second.
AUTO
OFF / ON
Operation Indication Lamps (LED)
POWER
(Green) ......... Lights up in operation,
blinks in Automatic
Operation Mode judging.
QUIET
(Orange) ......... Lights up in Quiet Mode
Operation.
TIMER
(Orange) ......... Lights up in Timer
Setting.
POWERFUL
(Orange) ... Lights up in Powerful
Mode Operation.
(Green) ............ Lights up in Ionizer
Mode Operation.
Operation Mode
Heating, Cooling, Soft Dry and Automatic
Mode.
Powerful Operation
Reaches the desired room temperature
quickly.
Time Delay Safety Control
Restarting is inhibited for appro. 3 minutes.
Starting Current Control
Quiet Operation
To provide extra quiet operation.
7 Minutes Time Save Control
Cooling Operation only.
Fan motor is delayed for 1.6 seconds when
compressor starts simultaneously.
30 Minutes Time Save Control
Heating Operation only.
Hot-Start Control
At Heating Operation the indoor fan will
operate at SLo speed when indoor heat
exchanger temperature reaches 30°C.
Anti Cold Draft Control
The indoor fan operates at SSLo when the
indoor heat exchanger temperature is low.
(During Heating mode thermal off)
4
CS-A7CKP CU-A7CKP5 / CS-A9CKP CU-A9CKP5 / CS-A12CKP CU-A12CKP5

Other manuals for Panasonic CS-A12CKP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-A12CKP and is the answer not in the manual?

Panasonic CS-A12CKP Specifications

General IconGeneral
BrandPanasonic
ModelCS-A12CKP
CategoryAir Conditioner
LanguageEnglish

Related product manuals