HOW TO OPERATE
To start the operation
Press 1.
POWER indicator (green) on the indoor unit will light up.
To stop, press once more.
Setting Mode
Press 2 to select:-
Cooling Model
AUTO Automatic Operation
COOL Cooling Operation
DRY Soft Dry Operation
FAN Air Circulation Operation
Heat Pump Model
AUTO Automatic Operation
HEAT Heating Operation
COOL Cooling Operation
DRY Soft Dry Operation
PREPARATION BEFORE OPERATION
Indoor Unit
1 Connect the power supply cord to an independent
power supply.
Setting Temperature
Press 3 to increase or decrease the temperature.
The temperature can be set between 16°C ~ 30°C
Recommended temperature:
During AUTO Operation, press 3 to select:-
Operation with 2°C higher than the standard
temperature.
Operation with the standard temperature.
Operation with 2°C lower than the standard
temperature.
Standard Temperature
Cooling Model
Once the Automatic Operation is selected, the indoor
temperature sensor operates automatically to select
the desired operation mode with Cooling or Soft Dry.
After the operation mode has been selected, the
mode does not change.
Heat Pump Model
At the beginning of the automatic operation, Heating,
Cooling or Soft Dry is automatically selected according
to the indoor temperature.
After the operation mode has been selected, the
mode does not change.
Operation
Cooling
Soft Dry
Standard
temperature
25°C
22°C
Indoor
temperature
23°C
Operation
Cooling
Soft Dry
Heating
Standard
temperature
25°C
22°C
21°C
Indoor
temperature
23°C
20°C
Cooling Model
COOL > 26°C ~ 28°C
DRY > 1°C ~ 2°C
lower than the
room temperature
Heat Pump Model
COOL > 26°C ~ 28°C
DRY > 1°C ~ 2°C
lower than the
room temperature
HEAT >20°C ~ 24°C
Operation Details
COOL Cooling Operation
To set the room temperature at your preference
cooling comfort.
AUTO Automatic Operation
Sense indoor temperature to select the optimum
mode.
Temperature is not displayed on the remote control
during AUTO operation.
DRY Soft Dry Operation
A very gentle Cooling Operation, prior to
dehumidification. It does not lower the room
temperature.
During Soft Dry operation, the indoor fan operates at
Low Fan Speed.
HEAT Heating Operation
(for Heat Pump Model only)
Heat is obtained from outdoor air to warm up the
room. When the outdoor ambient air temperature
falls, the heating capacity of the unit might be
reduced.
Defrosting Operation
Depend on the outdoor temperature, the operation
occasionally stops to melt the frost on the outdoor
unit.
FAN Air Circulation Operation
(for Cooling Model only)
Heated air rises and collects at the top of the room.
The air circulation circulates the heated air downward,
thus increasing heating effectiveness. When the unit
is installed floor mounted, you should set the
temperature higher than that of ceiling mounted.
At ceiling mounted At floor mounted
1

Table of Contents

Other manuals for Panasonic CS-A12CTP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-A12CTP and is the answer not in the manual?

Panasonic CS-A12CTP Specifications

General IconGeneral
BrandPanasonic
ModelCS-A12CTP
CategoryAir Conditioner
LanguageEnglish

Related product manuals