Page #78 background imageLoading...
Page #78 background image
Liquid
Compression
Protection,
Crankcase
Heater
Input
power
W 31-37 31-37 31-37 31-37 31-37 34-41
Compressor
OFF
°C 160 165 120* 115 135 120
Protection,
50Hz
Internal °C 165 165 - - 140 135
Protector
60Hz
ON °C
50Hz
90 102 90*
61
61 61
°C
60Hz
105 105 - - 61 61
Trip time
50Hz
5-15sec/
55A
5-15sec/
55A
- 10sec/44A 10sec/40A 10sec/40A
10sec
60Hz
3-9sec/
96A
3-9sec/
96A
- - 10sec/85A 10sec/85A
For Fan
Motor
Protection,
OFF °C 135 135 135 135 135 135
Internal
Protector
(49F)
ON °C 85 85 85 85 85 85
Heating
Pressure
Switch (Heat
OFF
MPa
2.35 2.35 2.35 2.35 2.35 2.35
Pump Only)
(Fan Speed)
(63H
2
)
ON
MPa
2.25 2.25 2.25 2.25 2.25 2.25
Cooling
Control,
Control
Th 30 degree celcius ----- High speed
Heat
Exchanger
method
Th < 30 degree celcius ------5 speed step control
Outlet Temp.
Thermistor
(Th2)
For Control
Protection,
Fuse
CUT A 6.3 6.3 6.3 6.3 6.3 6.3
1MPa = 10.2 kgf/cm
2 /
* Head Thermostat only for CU-A28BBP8 / CU-C28BBP8
14. COMPONENT SPECIFICATION
78

Other manuals for Panasonic CS-A18BB4P

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Panasonic CS-A18BB4P and is the answer not in the manual?

Panasonic CS-A18BB4P Specifications

General IconGeneral
BrandPanasonic
ModelCS-A18BB4P
CategoryAir Conditioner
LanguageEnglish

Related product manuals