Noise Level Cool dB (A) Hi 50 Me 47 Lo 45 Hi 56
Heat Hi 50 Me 47 Lo 45 Hi 58
1. Cooling capacities are based on indoor temperature of 27°C D.B.
(80.6°F D.B.), 19.C W.B. (66.2°F W.B.) and outdoor air
temperature of 35°C D.B. (95°F D.B.), 24°C W.B. (75.2°F W.B.)
2. Heating capacities are based on indoor temperature of 20°C D.B.
(68°F D.B.) and outdoor air temperature of C D.B. (44.6°F D.B.),
C W.B. (42.8°F W.B.)
ELECTRICAL DATA (50Hz)
ITEM / MODEL
CS-A50BB4P, CU-A50BBP8
Condition by JIS B 8615
Volts V 380 400
415
Phase 3N 3N 3N
Power Consumption kW Cool 4.99 4.99
4.99
Heat 4.97 4.97
4.97
Running Current A Cool 8.6 8.6 8.6
Heat 8.5 8.5 8.5
Starting Current A 69 69 69
Power Factor % Cool 88 84 81
Heat 89 84 81
*Power Factor means total figure of compressor, indoor fan motor and outdoor fan motor.
Panasonic Power source AC, 3N~380V, 400V, 415V
50Hz
4. SPECIFICATION (COOLING ONLY TYPE )
4.1. CS-A24BB4P / CU-C24BBP5