10
To learn more...
Operation mode
AUTO : During operation mode selection the POWER indicator blinks.
• Unit selects operation mode every 10 minutes according to setting temperature
and room temperature.
HEAT : Unit takes a while to warm up. The POWER indicator blinks during this
operation.
COOL : Provides effi cient comfort cooling to suit your needs.
DRY : Unit operates at low fan speed to give a gentle cooling operation.
FAN : To circulate air in the room.
i AUTO-X : The fast cooling is ideal when you come home on a hot day.
Energy saving temperature setting
Operating the unit within the recommended temperature range may save energy.
HEAT :
20.0 °C ~ 24.0 °C /
68 °F ~ 75 °F.
COOL : 26.0 °C ~ 28.0 °C / 79 °F ~ 82 °F.
Air fl ow direction
In COOL/DRY mode:
If AUTO is set, the fl aps swings up/down automatically.
In i AUTO-X mode:
If AUTO is set, the horizontal fl ap is fi xed at the lower position and shift to the upper
position after reaches set temperature. If manual is set, the horizontal fl ap are fi xed at the
predetermined position.
In HEAT mode:
If AUTO is set, the horizontal fl ap is fi xed at the predetermined position.
Auto restart control
If power is resumed after a power failure, the operation will restart automatically after a
period of time with previous operation mode and airfl ow direction.
• This control is not applicable when TIMER is set.
Operating conditions
Use this air conditioner in the temperature range indicated in the table.
Temperature
°C (°F)
Indoor Outdoor
DBT WBT DBT WBT
COOL
Max. 32 (89.6) 23 (73.4) 46 (114.8) 26 (78.8)
Min. 16 (60.8) 11 (51.8) 5 (41.0) -
HEAT
Max. 30 (86.0) - 24 (75.2) 18 (64.4)
Min. 16 (60.8) - -15 (5.0) -
DBT: Dry bulb temperature, WBT: Wet bulb temperature
ACXF55-11360_SM0717-0_EN.indd 10ACXF55-11360_SM0717-0_EN.indd 10 13/6/2017 11:54:32 AM13/6/2017 11:54:32 AM