3
Parker Hannifin
Pump and Motor Division
Trollhättan, Sweden
Service Manual
Series F11
Bulletin HY30-5503-M1/UK
1)
Intermittent: max 6 seconds in any one minute.
2)
Self priming speed valid at sea level.
Phased out
Specifications
Size 5 10 12 14 19 28 39 58 78 110 150 250
Displacement (cm
3
/rev) 4,9 9,8 12,5 14,0 19,0 28,1 38,7 58,2 78,2 110 150 242
Operating Pressure
Peak (bar)
Max continuous (bar)
420
350
420
350
420
350
420
350
420
350
420
350
420
350
420
350
420
350
420
350
420
350
420
350
Operating speed (rpm)
Max intermittent
1)
Max continuous
Min continuous
12000
10800
50
11000
9900
50
10200
9200
50
10000
9000
50
9000
8100
50
6500
5000
150
5200
4200
125
4500
3600
125
3500
3100
100
3300
2800
100
3000
2600
50
2700
2400
50
Pump self priming speed (rpm)
L or R operation
2)
4600 4200
3850 3500 3500
2800 2300 2200 1900 1600 1700 1500
Main circuit temp.
Max (°C)
Min (°C)
80
-40
80
-40
80
-40
80
-40
80
-40
80
-40
80
-40
80
-40
80
-40
80
-40
80
-40
80
-40
Weight (kg)
5 7,5 8,3 11 11 14 22,5 23 39 46 70 77
F11-250
F11 - 5
- 10
- 19
- 28
- 39
- 58
- 78
-110
-150
-250 See Fig.
Screw Tightening Torque.
F11-5 through F11-150
Series
See table
Tightening torque
(Nm)
24±4
48±8
48±8
60±10
105±20
105±20
220±35
220±35
220±35
220±35 Nm