PWSA 20-Li F4
GB
│
CY
│
3 ■
Package contents
1 cordless angle grinder 20 V
1 additional handle
1 blade guard (pre-assembled)
1 two-hole mounting spanner
1 cutting disc (pre-assembled)
1 set of operating instructions
Technical details
Cordless angle grinder 20 V PWSA 20-Li F4
Rated voltage 20 V (DC)
Rated idle speed n
0
2500–11000 rpm
Disc width Ø 125 mm
Thread size M14
Battery PAP 20 B3*
Type LITHIUM ION
Rated voltage 20 V
(DC)
Capacity 4 Ah
Cells 10
High-speed charger PLG 20 C3*
INPUT
Rated voltage 230–240 V ∼, 50 Hz
(AC)
Rated power
consumption 120 W
Fuse (internal) 3.15 A
T3.15A
OUTPUT
Rated voltage 21.5 V (DC)
Rated current 4.5 A
Charging time approx. 60 min.
Protection class II /
(double insulation)
* BATTERY AND CHARGER ARE NOT INCLUDED
Noise and vibration data
Noise measurement value determined in accord-
ance with EN 62841. The A-rated noise level of
the power tool is typically:
Noise emission value
Sound pressure level L
PA
= 83.6 dB (A)
Uncertainty K = 3 dB
Sound power level L
WA
= 94.6 dB (A)
Uncertainty K = 3 dB
Wear ear muffs!
Total vibration value
Surface grinding
main handle a
h, AG
< 2.5 m/s
2
Uncertainty K = 1.5 m/s
2
Surface grinding
Additional handle a
h, AG
< 2,5 m/s
2
Uncertainty K = 1.5 m/s
2
NOTE
►
The vibration emission values and the noise
emission values given in these instructions
have been measured in accordance with a
standardised test procedure and can be used
for comparison of the power tool with
another tool.
► The specified total vibration values and the
noise emission values can also be used to
make a provisional load estimate.
WARNING!
► Depending on the manner in which the
power tool is being used, and in particular
the kind of workpiece that is being worked,
the vibration and noise emission values can
deviate from the values given in these instruc-
tions during actual use of the power tool.
► It is necessary to establish safety measures to
protect the operator based on an estimation
of the vibration load during actual use (all
states of operation must be included, e.g.
times when the power tool is switched off and
times where the power tool is switched on but
running without load).