Color Sync Controller Installation Guide
General Installation Information
1. Allworkmustbeperformedbyalicensedelectricianorqualiedpoolprofessional,and
mustconformtoallnational,state,andlocalcodes.
2. Install to provide drainage of compartment for electrical components.
3. This equipment is not provided with integral Ground Fault Circuit Interruptors (GFCI)
protection.Whenthisequipmentisusedtopowerorswitchanunderwaterluminaire,
suitableGFCIprotectionshallbeprovidedintheeld.Luminairecircuitconductorsshall
notoccupytheconduit,boxesorenclosureswithothercircuitsunlesstheothercircuits
are also GFCI protected.
4. The electrical supply for this product must include a suitably rated switch or circuit
breaker to open all ungrounded supply conductors to comply with in accordance with the
currentNationalElectricalCode(NEC),NFPA70ortheCanadianElectricalCode(CEC),
CSA C22.1. All applicable local installation codes and ordinances must also be adhered
to. The disconnecting means must be readily accessible to the tub occupant but installed
atleast10ft.(3.05m)fromtheinsidewallofthepool.
2
3
WARNINGS AND IMPORTANT SAFETY PRECAUTIONS