Color Sync Controller Installation Guide
4
5
WARNINGS AND IMPORTANT SAFETY PRECAUTIONS
Be sure the pool electrical system conforms with all requirements of the
National Electrical Code (NEC), and all local codes and ordinances. A licensed
or certified electrician must install the electrical system to meet or exceed those
requirements before the Color Sync™ Controller is installed. The electrician
should also consult the local building department regarding local codes. Some of
the NEC requirements are listed below:
The Controller must be installed by a qualified electrician, according
to the National Electrical Code (including article 680) or Canadian
Electrical Code (including section 68) and, local code requirements.
For Canadian installations, supply circuit must be protected by a
ground fault circuit interrupter.
The Controller must be provided with a fail-proof ground as required
by NEC, Article 680 and any applicable local codes For Canadian
installations, the supply circuit must be protected by a ground fault
circuit interrupter.
Do not install the Controller within 5 feet (3 meters for Canadian
installations) of any body of water. USE COPPER CONDUCTORS
O N LY.
The Controller should be mounted at least 1 foot above the water and
ground level.
Do not exceed the maximum ratings of individual components, wiring
devices, and current carrying capacity of conductors.
For grounding and bonding the Controller and the installation, refer
to section 680 of the National Electrical Code or section 68 of the
Canadian Electrical Code.
The lighting circuit must have a Ground Fault Circuit Interrupter
(GFCI), and an appropriately rated circuit breaker.
The light fixture and all metal items within five (5) feet of the pool
must be properly electrically bonded.
The Controller must be properly electrically bonded and grounded.
Do not submerge the Controller.
Do not connect two or more Controllers together.