OPERATING THE PUMP 11/20
EXTERNAL CONTROL
This function is for programming speeds that will run when the IntelliComm® Communication
Center sends it a command. For example, Terminal 3 and 4 in the IntelliComm system will
correspond to External Control Program #1. (5 and 6 to Ext Ctrl #2).
The Stop Delay feature allows the user to program the pump to run a Program Speed after
the External Control has been deactivated. This feature can be used to provide a cooling down
period for the pump after a trigger signal from an installed heater has been deactivated. Each
individual Program Speed can have a Stop Delay of 1 to 10 minutes programmed.
Use the External Control feature to program the IntelliComm system power center.
To access the External Control menu:
1. Check that the green power LED is on.
2. Press the Menu button.
3. Use Up or Down arrow to scroll to “Ext. Ctrl.”.
4. Press Select. “Program 1” will display.
5. Press Select. “750 RPM” is displayed.
6. Press Select. The “RPM” number will highlight.
7. Press up or down arrow to change the RPM setting.
8. Press save to save the setting.
Note: To cancel any changes, press the back button to exit without saving.
9. If you do not wish to program a Stop Delay, continue to step 13. If you do wish to program
a Stop delay press Up or Down arrow to scroll to “Stop Delay”.
10. Press Select to set Stop Delay.
11. Use the Up or Down arrows to change the Stop Delay setting. Stop Delay can be set from
0 minutes (disabled) to 10 minutes.
12. Press Save to save the settings.
Note: To cancel any changes, press the back button to exit without saving.
13. Press Back to return to set Program 2.
14. Use Up or Down arrow to scroll to “Program 2”.
15. Repeat Steps 4 through 11 to set Program 2, 3, and 4.
22