MAINTENANCE
OPTIONAL DRAIN PUMP
If the oponal drain pump (63802A) is installed, test its
operaon at least twice a year as outlined below. Note that the
pump has power even when the control switch is in the “OFF”
posion.
If the oponal drain pump is not operang
properly, it will adversely aect performance, component life,
and warranty coverage and may result in costly water damage.
1) Move the control switch to the “OFF” posion, then
unplug the appliance from the electrical outlet
To reduce the risk of electric shock, do not
touch the control switch or plug with damp hands.
2) Remove all ice from the storage bin.
3) Plug the appliance back in.
4) Slowly pour 24 to 30 oz. (710 to 890 ml) of water over
the storage bin drain hole in the storage bin.
5) If water pumps out properly and the drain pump
then de-energizes, proceed to step 6. If water does
not pump out properly and/or the drain pump does
not de-energize, the appliance must be serviced by a
qualied service technician before proceeding.
6) Move the control switch to the “ICE” posion.
7) Pour another 24 to 30 oz. (710 to 890 ml) of water
into the appliance’s ice storage bin, then completely
restrict the discharge hose while the drain pump is
operang (See Fig. 26). Pour more water into the
appliance’s ice storage bin unl the appliance turns
o. The drain pump will connue to operate. Check
for leaks.
8) Remove the discharge hose restricon and allow the
water to be pumped out normally. Power to the
appliance will be restored when the water in the drain
pump returns to a normal level.
9) If the appliance fails to turn o with the discharge
hose restricted or the pump fails to pump out the
water, the appliance must be serviced by a qualied
service technician.
WARNING
DANGER
!
Fig. 26
Discharge Hose