- 19 -
Check whether the following assemblies are complete.
Name Quantity Note Remarks
Manual 1 —— /
Damping rubber 4 —— /
Pipe connection 2 —— /
Wire controller 1 —— LED / LCD
12. Installation information
Enough space for installation and maintenance shall be preserved.
The air outlet should be free from obstacles and strong wind.
The bearing surface should be flat, able to bear weight of the unit and suitable for
installing the unit horizontally without increasing noise or vibration.
No flammable gas is leaked nearby.
It is convenient for piping and wiring.
1) Installation position
Installing the equipment in any of the following places may lead to
malfunction of the equipment (if it is inevitable to consult the supplier):
The site contains mineral oils such as cutting lubricant.
Hot spring area where corrosive gases exist, e.g., sulfide gas.
Factories where the power voltage fluctuates seriously.
Place where strong electromagnetic waves exist.
Place where flammable gases or materials exist.
Place where acid or alkali gases evaporate.
Other special environments.
2) Precautions before installation
Decide the correct way of conveying the equipment.
Try to transport this equipment with the original package.
If the unit has to be installed on a metal part of the building, electric
insulation must be installed, and the installation must meet the relevant
technical standards for electric devices.
3) Installation space
Before installing the unit, reserve the space of maintenance.
The installation space should be convenient to install.
The installation space should with good ventilation.
The installation space should not to against air flow directly.
There must be drainage channel around the unit for condensing water.
The installation location should be better near power supply.
Try to close the swimming pool for the convenience of piping.
Parallel connection must be carried out when install several units
together.