Function description
Operating Manual PDP67 F 4 code
1001531-EN-06
11
4 Function description
4.1 Operation
Using the module PDP67 F 4 code/PDP67 F 4 codeVA, up to four PSENcode, PSENslock
and/or PSENini sensors can be connected in series and connected to an evaluation device.
4.1.1 Internal wiring diagram
6 I1
1 I2
2 24 V
7 0 V
5 Diag
8 Lock
3 O1
4 O2
6 I1
1 I2
2 24 V
7 0 V
5 Diag
8 Lock
3 O1
4 O2
6 I1
1 I2
2 24 V
7 0 V
5 Diag
8 Lock
3 O1
4 O2
6 I1
1 I2
2 24 V
7 0 V
5 Diag
8 Lock
3 O1
4 O2
4 n.c.
3 n.c.
8 n.c.
5 n.c.
7 0 V
2 24 V
1 I2
6 I1
1 Diag 1
5 Lock 1
2 Diag 2
6 Lock 2
3 Diag 3
7 Lock 3
4 Diag 4
8 Lock 4
X1
X2
X3
X4
X5 X6
4.1.2 Diagnostics
The LEDs indicate the statuses of the signal outputs (Diag) and the inputs for control com-
mands for magnetic guard locking (Lock).