Inputs/outputs
X5
Assignment
8-pin M12 female connector
for connecting to the safety
inputs of an evaluation
device
1: Input I2
2: 24 VDC (U
B
)
3: n.c.
4: n.c.
5: n.c.
6. Input I1
7. 0 V (U
B
)
8. n.c.
Inputs/outputs
X6
Assignment
8-pin M12 female connector
for connecting to the stand-
ard inputs and outputs of an
evaluation device
1: Signal output Diag 1
2: Signal output Diag 2
3: Signal output Diag 3
4: Signal output Diag 4
5: Input lock 1 (for control
command for magnetic
guard locking)
6: Input lock 2 (for control
command for magnetic
guard locking)
7: Input lock 3 (for control
command for magnetic
guard locking)
8: Input lock 4 (for control
command for magnetic
guard locking)