20
INSTALLATION CHECK LIST
WATER HEATER LOCATION
Centrally located with the water piping system. Located as close
to the gas piping and vent pipe system as possible.
Located indoors and in a vertical position. Protected from freezing
temperatures.
Proper clearances from combustible surfaces maintained and not
installed directly on a carpeted floor. Sufficient room to service
the water heater.
Provisions made to protect the area from water damage. Properly
sized drain pan installed and piped to an adequate drain.
Installation area free of corrosive elements and flammable
materials.
GAS SUPPLY AND PIPING
Only rigid piping used. No flexible or copper gas connections.
Gas supply is the same type as listed on the water heater data
plate.
Gas line equipped with full opening shut-off valve, union and drip
leg.
Approved pipe joint compound used.
Adequate pipe size and of approved material.
Chloride-free soap and water solution or other approved means
used to check all connections and fittings for possible gas leaks.
CONDENSATE LINE
Proper piping material.
Line sloped to adequate drain or approved condensate pump.
Protected from freezing (if required).
Properly vented.
WATER SYSTEM PIPING
Temperature and pressure relief valve properly installed with a
discharge line run to an open drain and protected from freezing.
All piping properly installed and free of leaks.
Heater completely filled with water.
Closed system pressure build-up precautions addressed.
If required, tempering valve or anti-scald device installed per
manufacturer’s instructions
ELECTRICAL
Unit connected to a dedicated 120 volt, 15 ampere supply.
Proper polarity.
Water heater properly grounded.
Installed per the latest edition of the National Electric Code,
ANSI/NFPA 70 or prevailing local codes.
VENT PIPE SYSTEM
Vent pipe and fittings of approved material.
Acceptable length and number of elbows on air inlet pipe.
Acceptable length and number of elbows on exhaust pipe.
Installed in accordance with “National Fuel Gas Code”, NFPA
54, ANSI Z223.1-Latest Edition or prevailing provisions of local
codes.
All horizontal piping sloped upward 1/4" per foot.
Not obstructed in any way.
VENT TERMINATION
CONCENTRIC
12" min. above grade/snow level
Exhaust pipe/air intake pipe sloped downwards toward water
heater.
HORIZONTAL
Correct relationship - exhaust to intake
12" min. above grade/snow level
Exhaust pipe/air intake pipe sloped downwards toward water
heater.
ALTERNATE HORIZONTAL
Correct relationship - exhaust to intake
12" min. above anticipated snow level
Exhaust pipe/air intake pipe sloped downwards toward water
heater.
VERTICAL
Intake - 12" min. above roof/snow level
Correct relationship - exhaust to intake.