42
CURRENT FAULT
DESCRIPTION/ACTION DISPLAY
Press Current Fault from the Main Menu and press the Operational
Button under "SELECT" to enter this menu. This menu contains non
adjustable operational information. Use the Slidebar to navigate the
menu.
This menu contains the current Fault or Alert error message. The
time the Fault or Alert message occurred appears directly below. A
brief description of what causes the particular Fault or Alert condition
appears below that. Pressing "ADVANCED" will give more detailed
service information and a list of possible causes for the Fault or Alert
condition. See “Fault And Alert Messages” beginning on Page 51 for
more detailed information and diagnostic procedures.
If there is no Fault or Alert condition active this menu will not contain
any information, "(none)" will be shown next to Current Fault in the
Main menu.
ADVANCEDBACK
0 days 0 hrs 0 mins ago
Error Code: A8-1201
Restriction in exhaust pipe.
Check exhaust pipe and
termination for blockage.
Press the Advanced button for
FAULT HISTORY
DESCRIPTION/ACTION DISPLAY
Press "Fault History" from the Main Menu to enter this menu. This
menu contains non adjustable operational information. Use the
Slidebar to navigate the menu.
This menu contains a list of the last nine (9) Fault and Alert messages
with a time stamp. The newest event will replace the oldest.
Press the Fault to view details for each Fault or Alert message
stored.
Fault History
HELPBACK
1: Upper Te mp Probe (Open) (47) >
0 days 2 hrs 37 mins ago >
2: Hardware Failure (1A) >
0 days 2 hrs 37 mins ago >
3: Upper Temp Probe (Open) (47) >
0 days 2 hrs 40 mins ago >
FAULT OCCURRENCE
DESCRIPTION/ACTION DISPLAY
Press Fault Occurrence from the Main Menu to enter this menu.
This menu contains non adjustable operational information. Use the
Slidebar to navigate the menu.
This menu contains a running total of how many times each Fault
condition has occurred since the water heater was rst installed.
NOTE: Historical data is stored in the conguration key. If this "key"
is replaced during servicing the historical data will be lost. The data
stored in the new conguration key will no longer reect the entire
history of the water heater.
HELPBACK
Ignition Failure 0 >
ECO 0 >
Blocked Intake Air 1 >
Blocked Exhaust 1 >
External Input 0 >
RESTORE FACTORY DEFAULTS
DESCRIPTION/ACTION DISPLAY
Press Restore Factory Defaults from the Main Menu to enter this
menu.
To restore the adjustable user settings to their factory default
settings press “YES.” The display will show text conrming the
factory default settings have been restored.
Press NO to exit the Restore Factory Defaults menu.
NoYes
Are you sure you want to restore
the system to the factory
defaults?