Should you encounter any problems, contact the Customer Service at (888) 919-0070 from 8 AM to 5 PM Mon. thru Fri.
EST. Extended operating days and hours during peak season requirements.
Should you encounter any problems, contact the Customer Service at (888) 919-0070 from 8 AM to 5 PM Mon. thru Fri.
EST. Extended operating days and hours during peak season requirements.
109
Fitting Gasket P58PF1520K01
P58284283W05
P58PF1510P01
P58PF1430W05
P58PF2820P01
P58PF1680W05
P58PF1720W05
P58PF1710W05
P58PF1700W05
P58PF1690W05
P58PF1730K01
1
1
1
1
1
1
1
1
1
1
Suction Fitting
Suction Fitting Washer
(SF Washer)
Fitting Lock Nut
Suction Fitting Cap
(SF CAP)
Return Fitting
Return Fitting Diverter
(RF Diverter)
RF Locking Ring
RF Elbow 90˚
RF Nut
1
2
3
4
5
6
7
8
9
10
1
RF Gasket
11
Item
Part Name
Qty
Part #
CP2000-C
1
4
1
2
1
1
1
1
1
1
4
Hose
P58150059W01
P58PF2960W05
P5842504500A
P58PP1768W05
P58182201W05
P58182501K01
P58PP2098W05
P58147800K01
P58037000K01
P581041080PR
P58GF90000K1
P58PF0620K01
Hose Clamp
Filter Pump Assembly
Vent Screw
Vent Screw O-Ring
Seal Top
Canister Gasket
Type D Filter Cartridge
O-Ring
(on hose connections)
GFCI Power Cord Set
13
14
RF Thrust Washer
12
15
16
17
18
19
20
21
22
1
Return Fitting plug (RF Plug)
23
Item
Part Name
Qty
Part #
CP2000-C
10 POOL PUMP DISASSEMBLY & STORAGE
(1) Unplug the Power Filter Pump. Release the RF Locking Ring (8). Remove the RF Diverter (7) from the Return Fitting (6)
and then plug the Return Fitting (8) with the RF Plug (23). Now, hand tighten the SF Cap (5) onto the Suction Fitting (2).
(2) Slowly unscrew the Vent Screw (16) from the Seal Top (18) allowing the filter pump to depressurize.
(3) Remove the Seal Top (18) by turning counter-clockwise.
(4) Remove the Filter Cartridge (21) and remove any chlorine tablets left inside the core section of the filter.
(5) Loosen all four Hose Clamps (14), remove the Hoses (13) and allow water to drain out.
(6) Clean and dry all filter pump parts including filter cartridges.
(7) Liberally lubricate the O-rings (17) at the Seal Top (18) and Gasket (19) on the canister with petroleum jelly, and then
reassemble it along with the Seal Top (18), Vent Screw (16) onto the canister. Store all filter parts carefully.
12 REPLACEMENT PART ORDERING INFO
11 LIMITED WARRANTY
Polygroup Limited (Macao Commercial Offshore), (hereinafter “Polygroup”) warrants to the original purchaser only, the
CP type Electric Filter Pump against defects in material and workmanship for 180 days from the date of purchase.
Original Purchaser must retain proof of such purchase in the form of an original store sales receipt and must produce
such upon request by Polygroup or its designated agents. Warranty claims cannot be processed without a valid proof
of purchase.
This Limited Warranty applies only to the original purchaser of the product and is limited solely to the repair or
replacement of the product, to be decided in Polygroup’s sole discretion. Consequential damages, including claims for
loss of water, pool chemicals, damage, or labor are not covered under this Limited Warranty.
This Warranty will be declared invalid should the Purchaser modify or repair the product themselves or by unauthor-
ized persons; use non-Polygroup parts or accessories with the product; use the product in contravention of the
manufacturer’s Instructions; use improper voltage; abuse the product in any way; or through accident or negligence.
Normal wear-and-tear is not covered under this Warranty, nor are acts of God outside the control of Polygroup.
IN NO EVENT SHALL POLYGROUP, THEIR AUTHORIZED AGENTS, RELATED ENTITIES, OR EMPLOYEES BE LIABLE TO THE
BUYER OR ANY OTHER PARTY FOR DIRECT OR CONSEQUENTIAL DAMAGES. Some states or countries, or others jurisdic-
tions do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or
exclusion may not apply to you.
IMPORTANT SAFETY INSTRUCTIONS
13
ASME COMPLIANT SUCTION FITTING INFORMATION
PSF-100A AND PSF-100B SUCTION OUTLET
FOR ABOVE GROUND POOL
(1) READ AND FOLLOW ALL INSTRUCTIONS
CAUTION! DO NOT EXCEED THE MAXIMUM ALLOWABLE FLOW RATE:
(1) PSF-100A and PSF-100B Suction Outlets are certified by IAPMO in accordance with the ASME/ANSI A112.19.8b-2009
Suction Fitting for use in Swimming Pools, Wading Pools, Spas, and Hot Tubs.
(2) This is a submerged suction outlet for use with above ground swimming pool.
(3) For single drain only. Use only ONE outlet for each pump.
(4) Do not locate this suction outlet on sitting areas or on the backrest for such seating area.
(5) Install this outlet at location recommended by the pool manufacturer.
(6) The maximum allowable flow rate of this suction outlet is 45 gallon per minute (2,700 gallonper hour).
(7) Connection Hose:
• Model PSF-100-A is to be connected with 1 1/4” (31.8mm) diameter hose.
• Model PSF-100-B is to be connected with 1 1/2” (38.1mm) diameter hose.
(8) The suction outlet is to be mounted at the suction outlet opening as specified by the manufacturer of the above
ground pool. The diameter of this opening should be within the range of 1.77” to 1.85” (45.0mm to 47.0mm). Refer to
the following diagram for detail assembly instructions:
(9) The suction outlet PSF-100A or PSF-100B is to be replace every 5 years.
(10) No tool is required for installation.
(11) Service and Winterizing Instructions
• 45 Gallon per minute (2,700 Gallon per hour).
• Carefully observe and inspect the suction outlet for damage and tampering before each use of the pool.
• Missing, broken or cracked suction outlet must be replaced before using the pool.
• Loose suction fitting should be reattached or replaced before using the pool.
• Remove and store Suction Outlet assembly if temperatures are expected to fall below 32° F.
READ, THEN KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE
Swimming Pool
Water Hose
Hose Clamp
Lock Nut, To Be Tightened By Hand
Rubber Gasket
Water Cap, To Be Installed Only During
Pump Maintenance Or Filter Change
Suction Fitting, PSF-100A Or PSF-100B
Flat Washer