6 Owner’s Manual for Portable Generator
Know Your Generator
Replacement owner’s manuals are available
at www.powermate.com.
Emissions
The United States Environmental Protection
Agency (US EPA) (and California Air
Resources Board (CARB), for engines/equip-
ment certified to California standards) requires
this engine/equipment to comply with exhaust
and evaporative emissions standards. Locate
the emissions compliance decal on the engine
to determine applicable standards. See the
included emissions warranty for emissions
warranty information. Follow the maintenance
specifications in this manual to ensure the
engine complies with applicable emissions
standards for the duration of the product’s life.
Connection Plugs
120 VAC, 20 Amp, Duplex
Receptacle
The 120 Volt outlet is overload protected by a
12 Amp push-to-reset circuit breaker. See Fig-
ure 2-4. Each receptacle will power 120 Volt
AC, single phase, 60 Hz electrical loads
requiring up to 1400 watts (1.4 kW) or 12
Amps of current. Use only high quality, well-
insulated, 3-wire grounded cord sets rated for
125 Volts at 20 Amps (or greater).
Figure 2-4. 120 VAC, 20 Amp, Duplex
Receptacle NEMA 5-20R
(000100a)
Consult Manual. Read and understand manual
completely before using product. Failure to
completely understand manual and product
could result in death or serious injury.
WARNING
Product Specifications
Generator Specifications
Rated Power @1.0 Power Factor 1.4 kW**
Surge Power 2.0 KVA**
Rated AC Voltage 120
Rated AC Load
Current @ 120V**
11.67
Rated Frequency 60 Hz @ 3600 RPM
Phase Single Phase
Weight (dry) 61.7 lb (28 kg)
** Operating Temperature Range: -12.2 deg. C (10 deg. F) to 40 Deg. C (104 Deg. F). When operated
above 25 deg. C (77 deg. F) there may be a decrease in power.
** Maximum wattage and current are subject to, and limited by, such factors as fuel Btu content, ambi-
ent temperature, altitude, engine condition, etc. Maximum power decreases about 3.5% for each
1,000 feet above sea level; and will also decrease about 1% for each 6° C (10° F) above 16° C (60°
F) ambient temperature.
Engine Specifications
Displacement 98 cc
Spark Plug Part No. 0K91470141
Spark Plug Type E6RTC or equivalent
Spark Plug Gap 0.028-0.031 inch or (0.70-0.80 mm)
Gasoline Capacity 8.5 L (2.25 gal)
Oil Type
See Chart in
Add Engine Oil
Oil Capacity 0.4 L (.42 qt.)
Run Time at 25% / 50% Load 14.5 Hours / 10.5 Hours
* Go to www.powermate.com
or contact an IASD for replacement parts.
000424

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Powermate PM2000 and is the answer not in the manual?

Powermate PM2000 Specifications

General IconGeneral
BrandPowermate
ModelPM2000
CategoryPortable Generator
LanguageEnglish

Related product manuals