LCA 76299211/144
"
Press key 4 and measure the second distance
(horizontal measurement).
The device displays the result in the summary
row and the respective measured distance to the
next measurement in the second row.
11 Troubleshooting
" If the message Error does not disappear
after switching on the device repeatedly,
please contact the dealer.
" If the message InFo appears with a number,
observe the instructions in the following
table.
12 Technical data
* under favourable conditions (good target
surface, room temperature) up to 10 m (33 ft).
Under unfavourable conditions such as bright
sunlight, a very weakly reflecting target surface
or large temperature fluctuations, the error can
increase to ± 0.25 mm/m (± 0.003 in/ft) for
distances over 10 m (33 ft).
12.1 Electromagnetic
compatibility (EMC)
Despite the compliance with all requirements of
the corresponding directives and norms, a
disturbance of other devices is possible.
12.2 FCC statement (applic. in
U.S.)
This equipment has been tested and found to
comply with the limits for a Class B digital
device, pursuant to part 15 of the FCC Rules.
These limits are designed to provide reasonable
protection against harmful interference in a
residential installation. This equipment
generates, uses and can radiate radio frequency
energy and, if not installed and used in
accordance with the instructions, may cause
harmful interference to radio communications.
However, there is no guarantee that interference
will not occur in a particular installation. If this
equipment does cause harmful interference to
radio or television reception, which can be
determined by turning the equipment off and
No. Cause Correction
204 Calculation error Perform measurement
again.
252 Temperature too high Let the device cool
down.
253 Temperature too low Warm the device up.
255 Reception signal too
weak, measuring time
too long
Change target surface
(e.g. white paper).
256 Input signal too high Change target surface
(e.g. white paper).
257 Measuring error, too
much background light
Shadow the target
area.
258 Measurement outside
of the measuring range
Mind the range.
260 Laser beam interrupted Repeat the
measurement.
Range 0.1 m to 30 m
0.33 ft to 98 ft
Measuring accuracy (2 σ) typ.: ± 2.0 mm*
± 0.08 in*
Smallest unit displayed 1 mm
0.08 in
Laser class 2
Laser type 635 nm, < 1 mW
Automatic switch-off after 180 s
Continuous measuring yes
Addition/Subtraction yes
Dimension (H x D x W) 123 x 50 x 26 mm
4.84 x 1.97 x 1.02 in
Battery durability
(2 x AAA)
up to 3000
measurements
Weight 100 g
Temperature range:
- Storage
- Operation
-25 °C to 70 °C
-13 °F to 158 °F
0 °C to 40 °C
32°F to 104°F
Warning
Possible disturbance of other devices
(e.g. safety equipment, medical equipment)
due to electromagnetic radiation!
" Observe the safety instructions of the respective
devices.
Storm.book Seite 11 Dienstag, 12. Februar 2008 8:52 08

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Prexiso X2 and is the answer not in the manual?

Prexiso X2 Specifications

General IconGeneral
BrandPrexiso
ModelX2
CategoryAnalytical Instruments
LanguageEnglish

Related product manuals