EasyManuals Logo
Home>ProKlima>Air Conditioner>01016

ProKlima 01016 User Manual

ProKlima 01016
24 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #3 background imageLoading...
Page #3 background image
3
3. Technical data
Cooling capacity* 2,500 watts
Energy efficiency* D (EER 2.62/COP -)
Air capacity 420 m
3
/h
Absorbed humidity 1.0 l/h
Timer 24 h
Operating voltage 220 - 240/50 V ~ Hz
Power rating: Cooling* 960 watts
Nominal power consumption, cooling 1,150 watts
Nominal current consumption, cooling 4.6 A
Compressor Rotary piston
Starting current 23 A
Outdoor temperature, cooling operation °C
+21 - +43 (DB)
Fluid line Ø A 6 mm
Suction pipe Ø A 9.52 mm
Length of refrigerant line supplied 4 m
Length of refrigerant line, max. 10 m
Max. difference in height between indoor/outdoor
device 5 m
Refrigerant R 407 C
Refrigerant filling capacity 500 g
Refrigerant refill quantity from 5 m 20 g/m
Sound pressure level
Inside ≤ 37 dB (A)
Outside ≤ 52 dB (A)
Dimensions
Inside 71 x 25 x 18 cm
Outside 72 x 43 x 26 cm
Weight
Inside 7 kg
Outside 25 kg
* data in accordance with EN 14511
Note: SPLIT 850 C does not have a heating function.
Anleitung SPLIT_850_C_GB:_ 10.11.2006 8:24 Uhr Seite 3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ProKlima 01016 and is the answer not in the manual?

ProKlima 01016 Specifications

General IconGeneral
BrandProKlima
Model01016
CategoryAir Conditioner
LanguageEnglish

Related product manuals