MAINTENANCE
BATTERY INSTALLATION
To avoid the false readings, replace the battery as soon as you suspect the
battery power to be low.
1) Turn the power off and disconnect the test leads from the meter.
2) Open the rear battery cover with a screwdriver.
3) Remove the old battery and insert the new battery into the battery holder,
observing the correct polarity.
4) Put the battery cover back in place and secure with the screws.
SPECIFICATIONS
Security Class: Cat II 1000V
Basic DCV Accuracy: 3.000%
DC Voltage: 100mV, 500mV, 2.5V, 10V, 50V, 250V, 1000V (±3.0%)
AC Voltage: 10V, 50V, 250V, 1000V (±4.0%)
DC Current: 50µA, 2.5mA, 25mA, 250mA (±3.0%)
Resistance: 2kΩ, 20kΩ, 200kΩ, 2MΩ, 20MΩ (±3.0%)
Measurement Type: Average
Input Impedence: 10Ω
Dimensions: 150(L) x 100(W) x 35(H)mm
Weight: 280g
Battery Type: 1 x 9V (included)
2 x AA (included)
BOX CONTENTS
1 x Multimeter
1 x Test Leads
1 x 9V Battery
2 x AA Batteries
1 x User Manual