EasyManuals Logo
Home>Pylontech>Camera Accessories>US2000

Pylontech US2000 User Manual

Pylontech US2000
40 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #36 background imageLoading...
Page #36 background image
33
then try measure voltage of power port at turn off and turn on mode and
remark the result. Switch off the module and contact your local distributor.
6) After switch On, the module turns on directly
j) BMS failure.
Solution Switch off the module and contact your local distributor.
Excluding the points above, if the faulty is still cannot be located, turn off
battery and repair.
6. Emergency Situations
1) Leaking Batteries
If the battery pack leaks electrolyte, avoid contact with the leaking liquid or
gas. If one is exposed to the leaked substance, immediately perform the
actions described below.
a) Inhalation: Evacuate the contaminated area and seek medical attention.
b) Contact with eyes: Rinse eyes with flowing water for 15 minutes and
seek medical attention.
c) Contact with skin: Wash the affected area thoroughly with soap and
water and seek medical attention.
Ingestion: Induce vomiting and seek medical attention.
2) Fire
NO WATER! Only dry powder fire or carbon dioxide extinguisher can be
used; if possible, move the battery pack to a safe area before it catches fire.
3) Wet Batteries
If the battery pack is wet or submerged in water, do not let people access it,
and then contact Pylontech or an authorized dealer for technical support.
Cut off all power switch on inverter side.
4) Damaged Batteries
Damaged batteries are dangerous and must be handled with the utmost

Other manuals for Pylontech US2000