Page 11
Contact SegenSolar (PTY) Ltd | e: info@segensolar.co.za | t: 08780 20663
Item Amount
Rated
Power(kW)(1)
Max Power(kW,
60S)
Peak Power(kW,
15S)
Nominal
Capacity(kWh)
Usable
Capacity(kWh)
Min. Back-
up time(2)
US3000C
1 1.8 3.6 4.3 3.6 3.4
1.9hrs
2 3.6 7.1 8.6 7.1 6.7
3 5.3 10.7 13.0 10.7 10.1
4 7.1 14.2 17.3 14.2 13.5
5 8.9 17.8 21.6 17.8 16.9
6 10.7 21.3 25.9 21.3 20.2
7 12.4 24.9 30.2 24.9 23.6
8 14.2 28.4 34.6 28.4 27.0
9 16.0 32.0 38.9 32.0 30.4
10 17.8 35.5 43.2 35.5 33.7
11 19.5 39.1 47.5 39.1 37.1
12 21.3 42.6 51.8 42.6 40.5
13 23.1 46.2 56.2 46.2 43.9
14 24.9 49.7 60.5 49.7 47.2
15 26.6 53.3 64.8 53.3 50.6
16 28.4 56.8 69.1 56.8 54.0
(1) Rated Power is based on ideal operation temperature(10 - 45
℃
)
,
during charging the power will leveling decrease when reaching full
capacity.
(2) Min. Back-up time is based on rated power and related condition during beginning of life, in real application please consider the load.
Quotation Item:
1.Battery Module(US3000C/UP5000) –varying amount depends on application.
2.External Cable kits–1 kit per 5kW installation.
3.Brackets/Cabinets –if necessary.
Residential Configuration